Full Maintenance and Battery Replacement on Kohler 20RCA Generator in Chatham, NJ

Klas Electric: Your Reliable Partner for Generator Maintenance in Chatham, NJ

We are excited to introduce our specialized annual maintenance service for generators, dedicated to ensuring your home's power remains steadfast, especially during crucial times.

Why Opt for Our Annual Maintenance Service in Chatham, NJ?

In Chatham, NJ, unpredictable weather events and unforeseen situations can disrupt your power supply. Our annual maintenance service is thoughtfully designed to keep your Kohler 20RCA generator operating at peak performance, ready to provide dependable backup power whenever you need it. Here's why regular maintenance is essential:

Reliability: Our service ensures your generator starts promptly and functions seamlessly during power outages, offering a reliable source of electricity for your home.
Longevity: Like any mechanical equipment, generators need regular care to ensure they last. Our skilled technicians conduct thorough inspections, address potential issues, and extend the lifespan of your generator.
Efficiency: Well-maintained generators operate efficiently, saving on fuel costs while delivering consistent power. This also contributes to a more environmentally friendly approach.


The Vital Role of Battery Replacement:

One crucial aspect of our annual maintenance service is battery replacement. A well-functioning battery is essential for your generator's reliable starting capability. Over time, batteries can degrade, potentially causing your generator to fail when you need it most. Our experts in Chatham, NJ, ensure your generator's battery is in excellent condition or replace it as needed, providing peace of mind and uninterrupted power.

Contact Us for Expert Generator Maintenance in Chatham, NJ:

Don't wait for a power outage to realize your generator isn't prepared. Contact Klas Electric today to schedule your Kohler 20RCA generator's annual maintenance service in Chatham, NJ. Our dedicated technicians will ensure your generator is ready to provide consistent power for your entire household.

For reliable, professional, and efficient whole house generator maintenance in Chatham, NJ, trust Klas Electric. Reach out to us to learn more about our services and schedule your maintenance appointment. Invest in peace of mind – let Klas Electric secure your power supply in Chatham, NJ.

Job Locations and Reviews

Chatham, NJ - Completed visual inspection on Kohler 14RCA. No issues were detected at the time of service.
Antoinette G.
Antoinette G. Checked in
Completed visual inspection on Kohler 14RCA. No issues were detected at the time of service.
Chatham, NJ 07928
Chatham, NJ - Completed full service on Kohler 20RESD. Replaced battery due to age. Unit is in working order and ready to operate in event of an outage.
Antoinette G.
Antoinette G. Checked in
Completed full service on Kohler 20RESD. Replaced battery due to age. Unit is in working order and ready to operate in event of an outage.
Chatham, NJ 07928
Antoinette G.
Antoinette G. Checked in
Installed dedicated line to customer supplied electric vehicle charging station.
Chatham, NJ 07928
Chatham, NJ - Completed full service on Kohler 20RESAL. No issues were detected at the time of service. Generator is in auto and ready to protect home in event of an outage.
Antoinette G.
Antoinette G. Checked in
Completed full service on Kohler 20RESAL. No issues were detected at the time of service. Generator is in auto and ready to protect home in event of an outage.
Chatham, NJ 07928
Chatham, NJ - Completed full service on Kohler 20RESD. No issues were detected at the time of service.
Antoinette G.
Antoinette G. Checked in
Completed full service on Kohler 20RESD. No issues were detected at the time of service.
Chatham, NJ 07928
Chatham, NJ - Completed full maintenance on Kohler 20RCA. Generator was in need of generator battery to be replaced. Generator is in auto and ready to protect home in event of an outage.
Antoinette G.
Antoinette G. Checked in
Completed full maintenance on Kohler 20RCA. Generator was in need of generator battery to be replaced. Generator is in auto and ready to protect home in event of an outage.
Chatham, NJ 07928
Chatham, NJ - Client called re: Carbon monoxide detectors going into alarm during power outage. 

We found this unit with exhaust aimed at the house and within 8’ of the intake vent and 59” from dryer vent. - all NFPA37 violations. 

Generators exhaust must be aimed away from or parallel to structure and must be minimum 10’ from intake vents and generators must be 5’ minimum from building openings. 

Luckily this client had CO2 detectors which alerted them and potentially saved their lives.
Antoinette G.
Antoinette G. Checked in
Client called re: Carbon monoxide detectors going into alarm during power outage. We found this unit with exhaust aimed at the house and within 8’ of the intake vent and 59” from dryer vent. - all NFPA37 violations. Generators exhaust must be aimed away from or parallel to structure and must be minimum 10’ from intake vents and generators must be 5’ minimum from building openings. Luckily this client had CO2 detectors which alerted them and potentially saved their lives.
Chatham, NJ 07928
Chatham, NJ - Completed full service on installation customer for Kohler 14RCA. No issues were detected at the time of service. Generator is in auto and ready to protect the home in event of an outage.
Antoinette G.
Antoinette G. Checked in
Completed full service on installation customer for Kohler 14RCA. No issues were detected at the time of service. Generator is in auto and ready to protect the home in event of an outage.
Chatham, NJ 07928
Chatham, NJ - Oil topper completed due to outage for nearly 2 days for service customer. Generator was in auto on arrival homeowners got power back around 10pm the evening prior. Oil level was slightly low added 1/4qt to get back to 100% gave customer rest of quart upon request.

While on site tech noticed battery on generator being charged at 14VDC through controller and 15VDC was found at battery posts. Removed and replaced RDC2 controller to prevent overcharging of battery new controller charges battery at the standard 13.4VDC.

Generator is 3 years old and under parts warranty customer agreed to pay the 1hr labor to to install and program new controller if Kohler refuses to pay labor in warranty claim. But I did relay to customer we would attempt to have Kohler pay for labor.

Generator in auto ready to go control replaced at 77hrs
Antoinette G.
Antoinette G. Checked in
Oil topper completed due to outage for nearly 2 days for service customer. Generator was in auto on arrival homeowners got power back around 10pm the evening prior. Oil level was slightly low added 1/4qt to get back to 100% gave customer rest of quart upon request. While on site tech noticed battery on generator being charged at 14VDC through controller and 15VDC was found at battery posts. Removed and replaced RDC2 controller to prevent overcharging of battery new controller charges battery at the standard 13.4VDC. Generator is 3 years old and under parts warranty customer agreed to pay the 1hr labor to to install and program new controller if Kohler refuses to pay labor in warranty claim. But I did relay to customer we would attempt to have Kohler pay for labor. Generator in auto ready to go control replaced at 77hrs
Chatham, NJ 07928
Antoinette G.
Antoinette G. Checked in
Service customer's generator has been running for nearly 24 hours and they are not home. We ran a service call to check oil levels. We added 1/2 quart of oil and put generator back in auto to continue supplying power to the home.